Coated optical sensing fibre supplied by Sensuron in strain and temperature variants across six coating and diameter options.

Sensuron offers the sensing fibre that its DFOS interrogators read. Two coating families are listed: ORMOCER at 195 um and 120 um for strain sensing, ORMOCER-T at the same two diameters for temperature sensing, and GFRP at 0.5 mm and 1.0 mm for strain sensing. The coating choice determines whether the fibre couples mechanical strain or is thermally decoupled for temperature measurement. No further optical specifications are published on the website.
| Parameter | Value |
|---|---|
| ORMOCER coated fibre diameters (strain sensing) | 195 and 120 um |
| ORMOCER-T coated fibre diameters (temperature sensing) | 195 and 120 um |
| GFRP coated fibre diameters (strain sensing) | 0.5 and 1.0 mm |

Consumable kit for cleaning fibre connectors and preparing fibre for splicing.

Tool kit containing the equipment needed to splice sensing fibre in the field or lab.

Consumable kit containing the adhesives and preparation materials required to bond sensing fibre to a test article.