Fiber optic, photonic & electronic test & measurement
FiberLabs

L-band amplifier (EDFA, 1U Rack Mount)

A 19-inch 1U rack-mount L-band EDFA that pairs with the C-band AMP-FL501x-CB rack units to extend WDM transmission bandwidth beyond the C-band.

L-band amplifier (EDFA, 1U Rack Mount)

Technical overview

The AMP-FL5001-LB series covers 1560 to 1610 nm at a 1580 nm nominal wavelength in four output grades from >= +13 dBm to >= +22 dBm, with gain from >= 25 to 35 dB and NF <= 6 dB. The 43 x 440 x 403 mm chassis uses SC/PC connectors on G.652 SMF, redundant hot-swap AC power, RS-232C with an alarm relay, and carries IEC 60825-1 and CE marking.

Features

  • Proven in Various Deployment Conditions (from R&D to Actual Network)
  • Monitoring/Logging/Interlocking Function
  • RS-232C
  • SNMP Option

Specifications

Specifications
ParameterValue
Product numbersAMP-FL5001-LB-13 / -16 / -19 / -22
Operating wavelength1560 to 1610 nm
Nominal wavelength1580 nm
Output power (input 0 dBm at nominal wavelength)>= +13 / >= +16 / >= +19 / >= +22 by grade dBm
Gain (input -30 dBm at nominal wavelength)>= 25 (-13) / >= 30 (-16) / >= 35 (-19, -22) dB
Noise figure (input -30 dBm at nominal wavelength)<= 6 dB
Input/output fiberSMF, G.652 compliant (e.g. SMF28)
Standard connectorSC/PC
Input/output isolatorBuilt In
Standard dimensions (H x W x D)43 x 440 x 403 mm
Safety functionInterlock with input level Alarm
Control modeACC (Auto Current Control) and ALC (Auto Light Control)
Remote interfaceRS-232C / Relay terminal for alarm
Operating temperature0 to 40 degC
Storage temperature-10 to 60 degC
Power supplyAC 100 to 240 V (50/60 Hz), Redundant and Hot-Swap
Humidity5 to 80 % RH (non-condensing)
Safety standardsIEC 60825-1 (JIS C 6802) / CE marking (EN 61010-1 / EN 61326-1)
Specifications are reproduced from the manufacturer's own published material on the date shown and are subject to change. Confirm at order.

Applications

  • Telecom Network
  • Datacom Network
  • Increasing Link Budget
  • Loss Compensation
Manufacturer datasheet (PDF)

You may also like

Need help specifying this?

Our application engineers will confirm specifications with the manufacturer and quote for your configuration.

Request Info