Technical overview

The AMP-FL5201-SB series covers 1460 to 1500 nm (1480 nm nominal) and the AMP-FL5221-SB series covers 1470 to 1520 nm (1490 nm nominal), in output grades from >= +13 dBm to >= +19 dBm with typical gain from 13 dB to 30 dB and noise figure <= 7 dB. The AMP-FL5221-SB-19-W adds <= 3 dB gain flatness. The 43 x 440 x 403 mm chassis uses SC/PC connectors, redundant hot-swap AC power and RS-232C with an alarm relay.

Features

  • Only S-band Fiber Amplifier in Market
  • High Gain and Low NF
  • Monitoring/Logging/Interlocking Function
  • RS-232C
  • SNMP Option

Specifications

Specifications
ParameterValue
Product numbersAMP-FL5201-SB-13 / -16 / -19; AMP-FL5221-SB-16 / -19 / -19-W
Operating wavelength (5201-SB)1460 to 1500 nm
Operating wavelength (5221-SB)1470 to 1520 nm
Nominal wavelength1480 (5201-SB) / 1490 (5221-SB) nm
Output power (input 0 dBm at nominal wavelength)>= +13 / >= +16 / >= +19 by grade dBm
Gain (input -30 dBm at nominal wavelength)Typ. 13 (5201-SB-13) / Typ. 16 (5201-SB-16) / Typ. 19 (5201-SB-19) / Typ. 25 (5221-SB-16) / Typ. 30 (5221-SB-19) / Typ. 24 (5221-SB-19-W) dB
Noise figure (input -30 dBm at nominal wavelength)<= 7 dB
Gain flatness (5221-SB-19-W)<= 3 (gain difference of 1471 and 1511 nm with 1471/1491/1511 nm signals at 0 dBm/ch) dB
Input/output fiberSMF, G.652 compliant (e.g. SMF28)
Standard connectorSC/PC
Input/output isolatorBuilt In
Standard dimensions (H x W x D)43 x 440 x 403 mm
Safety functionInterlock with input level Alarm
Control modeACC (Auto Current Control) and ALC (Auto Light Control)
Remote interfaceRS-232C / Relay terminal for alarm
Operating temperature0 to 40 degC
Storage temperature-10 to 60 degC
Power supplyAC 100 to 240 V (50/60 Hz), Redundant and Hot-Swap
Humidity5 to 80 % RH (non-condensing)
Safety standardsIEC 60825-1 (JIS C 6802) / CE marking (EN 61010-1 / EN 61326-1)
Specifications are reproduced from the manufacturer's own published material on the date shown and are subject to change. Confirm at order.

Applications

  • Telecom Network
  • Datacom Network
  • Increasing Link Budget
  • Loss Compensation
Manufacturer datasheet (PDF)

You may also like

Need help specifying this?

Our application engineers will confirm specifications with the manufacturer and quote for your configuration.

Request Info